DC Charging Pile Enclosures: Thermal and Weather Protection Design

DC Charging Pile Enclosures: Thermal and Weather Protection Design

A lot of power electronics in a DC fast-charging station is packed into a floor-standing cabinet which is usually placed outside. The main two loads on such a cabinet are the heat it generates while charging and the weather when it is not charging.

Each of these forces pushes against the others. A vent for cooling will allow rain to enter. A seal to keep water out will trap heat. So no single part can solve both problems. Enclosures are designed as a total system including airflow paths, sealing, gauge and coating and must be designed this way before the first panel is cut.

SanJun Hardware is a China custom sheet metal enclosures manufacturer with a 5,000 square meters ISO 9001 certified factory located in Guangdong, China. We are one of the leading China custom enclosures manufacturers, specialize in producing custom metal parts and all kinds of enclosures since 2010. In this article, we will introduce how we integrate thermal protection and weather resistance into the charging pile enclosure when manufacturing for DC fast charging piles of 60kW and above.

Two Loads Every DC Charging Pile Enclosure Must Handle

Heat Load at Fast-Charging Sites

Power modules, contactors and cables continue to generate heat whilst charging a vehicle. Additionally the cabinet shell creates solar gain and the temperature within the station will increase in high summer ambient temperatures.

The derating of the electronics with temperature, plus the shorter life of capacitors and connectors, means that even a cabinet which has passed a 25 °C test in the factory can fail prematurely at a roadside in August.

Weather Exposure and Ingress

Wind-driven rain and dust, condensation etc. attempt to penetrate the enclosure. Also the day/night variation in temperature can bring moisture into the cabinet, which will deposit on busbars and connectors. At coastal locations or on roads with salted ice the normal stress on the cabinet is even increased by corrosion.

Instead of penetrating through holes in the sheet metal, water more often enters an enclosure via cable entries, leaks through seam joints in doors or simply because unsupported gasket joints have shifted.

Thermal Design: Moving Heat Out of the Enclosure

Airflow Paths and Vent Placement

Normal airflow is from bottom to top in a cabinet that has heat rise. Cool air will enter into the low side louvers and then travel through the power modules and then exit from the top of the cabinet or roof. Intake points are located remote from the exhaust points to prevent short circuiting of the exhaust air back through the intake.

The angle of the blades of the louver determines the amount of airflow while at the same time shedding rain. The design of the louver must be such that there is a good balance between these two requirements. The size of the vent opening is determined by the calculated heat load of the contents of the cabinet. If a cabinet is too tightly sealed then it will cook its contents. But if a cabinet is opened too wide then weather will enter with all its ill effects. All this can be calculated but will vary from a sheltered charger to an open roadside charger.

Fan Mounts and Filtered Intakes

Convection cooling is able to move low amounts of heat. More powerful power modules require forced air cooling. Thus in panel manufacturing instead of drilling holes later in the panel for fans, the holes are cut as part of the panel fabrication.

A filtered intake is typically worse than an open intake for pressure loss but does keep clean air in the cabinet and dust out. A filter that is never cleaned can become a heat issue and it’s better to service the filter without opening the main cabinet. To dissipate heat within the cabinet, it is typical to add channels and to orient baffling to direct airflow to the hottest portions of the system rather than to collect in a corner. For particularly harsh sites, a heat exchanger or air conditioner can be integrated into the structure.

Custom EV charger enclosure with cable entry and connector detail on stainless frame

Weather Protection: Sealing, Drainage, and Coatings

Our standard packages are custom engineered on a project-by-project basis and are not stocked in a catalog. For example, our fabrication of 전기차 충전기 케이스 could be produced as pedestal, wall-mounted or pole-mounted versions, each with an optimized sealing solution for its particular location.

Sealing and Cable Entries

The majority of our charging pile enclosures are supplied with an IP54/55 sealed enclosure. However for sites that require additional protection our charging pile enclosures can be designed to include extra gaskets, sealed glands etc. to achieve an IP65 rating as required.

The worst part of a seal is usually its weakest area. A gasket on the other hand is running in a continuous groove. Joints are placed as far away from corners as possible to prevent leakage. A door for example is sealed by compressing a gasket in a smooth even motion over its entire travel. The latch point is positioned as close as possible to the edge of the seal to apply even pressure to it.

Special attention must be given to cable entries. Each cable must be provided with a sealed gland as well as with suitable strain relief. In addition to this, drainage must also be designed. The roof must be designed to allow water to run off, and any internal cavities that get wet must allow water to drain from them.

Coatings and Corrosion Resistance

A weather-resistant powder coating of 60-80 μm is applied to outdoor cabinets over a surface that has been properly pretreated. In addition to coating, degreasing and phosphating must first be carried out and checked for adhesion. The cross-hatch test as well as corrosion tests under salt-spray are typical pre-production tests for paint finishes.

Material and Gauge Choices

Selection of suitable materials depends on the specific project conditions and budget available. Each suitable material has its own cost-weight-corrosion-resistance-workability balance.

재료

Where it fits

Trade-offs

SPCC cold-rolled steel with powder coat

Sheltered and indoor installations

Lowest cost finish; requires a suitable sound coating cycle for outdoor use.

SGCC galvanized steel

General outdoor sites, common default

The zinc coating can provide some protection to exposed cut edges. The material is heavier than aluminum.

SUS304 stainless

High-humidity, or frequently cleaned sites

Good corrosion resistance; higher material and forming cost

Aluminum 5052

Weight-sensitive or pole-mounted units

Light, quick to spread heat. It’s easy to dent it instead of cutting steel.

Light-duty enclosures are designed with 1.2 mm material while higher power enclosures or locations prone to extreme vandalism would be designed with 3.0 mm material for added rigidity. Heavier gauge material costs more to bend and to ship so we only design with the required material gauge for the specific location where the unit will be installed.

Sheet metal ventilation fan grille panel with two circular fan cutouts and dimension callouts

What to Specify When Ordering a Custom Charging Enclosure

Clearly defining the specifications for Charging Enclosures saves a lot of time in every project. Here are the SanJun Hardware specifications that are used to define scope for Charging Enclosures from initial RFQ through production completion.

Heat load and module layout in order to dimension vent area and airflow path.

Ambient temperature range and whether the site is exposed, open or coastal.

Target ingress rating, stated as a number such as IP54 or IP65 rather than "weatherproof".

Mounting method: floor-standing pedestal, wall-mounted, or pole-mounted.

Cable entry positions and cable sizes as per the wiring plan.

Panel cutouts for screen, card reader and emergency stop buttons.

Coating specification, color, and any branding.

Quantity tier – Prototypes are priced differently than volume runs.

We pre-review your drawings/module specifications for potential manufacturability problems and tolerance issues before we produce Standard enclosures within 7 to 15 working days. Custom made structural cases are produced within 20 to 30 working days and above depending on case complexity. We even produce single prototypes as a first piece order for your starting ordering of a prototype.

결론

Thermal performance and weather protection need to be designed as two halves of one feature in the airflow path, with effective sealing, appropriate gauge and the correct coating. A cabinet at a roadside site is as quiet as a mouse during the hot summer months if designed correctly but absolute silence can never be recovered from should it go wrong and field service is unable to put right the inevitable lost life.

산준 하드웨어 can provide custom DC fast charging enclosures to OEMs and Charging Station Operators as well as DFM review and surface finish review. We would be happy to perform an engineering review of your drawings or module specs to provide you with an assessment to support your charging project.

자주 묻는 질문

Q: Can a DC charging pile enclosure reach IP65?

A: Yes. Standard Sealing packages are rated for IP54 / IP55. Harsher applications can be catered for by using upgraded gaskets, sealed cable glands etc. with suitable Ingress Protection to achieve an IP65 rating. This must be formally tested and verified to the Ingress Protection rating specified prior to despatch.

Q: How is overheating prevented inside a ventilated enclosure?

A: Convection only needs to be enabled for low heat loads in very densely packed systems. Low side intakes, such as those formed by low side louvers, can be coupled with high level outlets or even a roof vent to create effective airflow through the system. Internal channels can then be created to direct the airflow to the highest temperature area of the system and mounts provided for fans and for filtered intakes on the low side.

Q: What lead time should I expect for a custom charging enclosure?

A: Standard stock items typically ship within 7-15 working days. Custom made structural stock items have longer lead times, typically 20-30 working days or more, depending on size, gauge and any special finishes required. Prototypes are made first even for single item orders. They will then ship when completed.

Q: We have module specifications but no enclosure drawings. Can you design the enclosure?

A: Yes. Drawings, 3D models, or hand sketches with key dimensions are all enough to start. The engineering team reviews manufacturability, proposes structure optimizations, and confirms production-ready drawings before cutting. Prototype orders start at one piece, and sample costs can be applied to volume orders.

태그:

댓글을 남겨주세요

    이름*
    이메일 주소*
    귀하의 전화번호*
    WhatsApp *
    메시지*
    선택된 파일이 없습니다

    목차

    자주 묻는 질문

    네. 최소 주문 수량(MOQ)은 1개이며, 금형 제작이 필요 없습니다. 모든 맞춤형 판금 케이스는 고객님의 디자인에 따라 직접 생산 가능합니다.
    네, 고객님의 2D/3D 도면을 기반으로 맞춤형 판금 제작을 진행합니다. 무료 DFM(설계 제조성 검토) 서비스를 제공하며, 고객님의 정확한 재료, 공차 및 마감 요구 사항을 준수합니다. 시제품 제작 및 양산 모두 가능하며, 철저한 품질 관리와 수출 표준 포장을 제공합니다.
    물론입니다. 제품 크기, 조립 기능, 사용 시나리오 및 성능 요구 사항을 보내주시면 저희 판금 팀에서 무료 구조 설계, 솔루션 최적화 및 DFM 분석을 제공해 드립니다. 도면을 직접 준비하실 필요가 없습니다. 스케치부터 생산 도면까지 모든 설계 작업을 저희가 완료하여 연구 개발 비용과 위험 부담을 줄여드립니다. 고객의 조립 요구 사항을 완벽하게 충족할 수 있도록 도면을 반복적으로 수정합니다.
    당사는 고객님의 기술 요구사항을 접수하는 즉시 24시간 이내에 DFM 도면 검토 및 공식 견적을 제공합니다.
    네. 저희는 고객님의 도면에 따라 신속한 시제품 제작 서비스를 제공하여 대량 주문 전에 구조와 크기를 확인하실 수 있도록 도와드립니다.
    당사의 모든 제품은 ISO9001, EMC, LVD 및 RoHS 인증을 획득했습니다. 당사는 글로벌 안전 및 품질 기준을 완벽하게 준수하며, 모든 프로젝트 적용 분야에 안정적이고 신뢰할 수 있는 솔루션을 제공합니다.
    저희는 자체 공장을 운영하며 원스톱 종합 생산 서비스를 제공합니다. 엄격한 공정 관리와 표준화된 품질 관리는 안정적인 제품 품질과 정시 납품을 보장하여 신뢰할 수 있는 장기적인 글로벌 파트너십을 구축합니다.
    당사는 스테인리스강(304/316), 알루미늄(5052/6061), 냉간/열간 압연강, 아연 도금강, 황동 및 구리를 포함한 다양한 표준 및 고성능 판금 소재를 가공합니다. 또한 프로젝트 요구 사항에 따라 특수 소재를 조달할 수도 있습니다.
    레이저 절단 및 벤딩 가공의 표준 공차는 ±0.1mm입니다. 고정밀 부품의 경우, 재질 두께 및 부품 구조에 따라 ±0.05mm까지 정밀도를 확보할 수 있습니다. 모든 치수는 고객의 요구 사항을 충족하기 위해 출고 전 100% 검사됩니다.
    네, 저희는 분체 도장, 도색, 아노다이징, 샌드블라스팅, 브러싱, 전기 도금, 부동태 처리, 연마 및 열처리 등 모든 표면 처리 서비스를 원스톱으로 제공합니다. 고객님의 디자인에 따라 색상과 효과를 맞춤 제작할 수 있습니다.
    네, 저희는 고객으로부터 도면이나 설계 세부 정보를 받기 전에 항상 기밀유지협약(NDA)을 체결합니다. 저희는 고객의 지적 재산권을 엄격하게 보호하고 모든 프로젝트 정보를 기밀로 유지합니다.
    최신 제품

    저희 제품을 확인해 보세요

    더 보기
    Custom stainless steel equipment chassis enclosure with white powder-coated finish, top ventilation holes and side cable glands

    Custom Stainless Steel Welded Equipment Chassis & Cabinet Enclosure — Ventilated, Burr-Free, Cable-Entry-Ready Sheet Metal Housing for Industrial Electronics | OEM/ODM

    <p>We specialize in custom welded stainless steel equipment chassis, cabinet and enclosure manufacturing for industrial electronics.</p> <p>Backed by a full suite of professional sheet metal processes — laser cutting, precision stamping, CNC bending, argon-arc welding and surface treatment — our custom stainless steel enclosures deliver superior structural strength, outstanding corrosion resistance and burr-free edges.</p> <p>Engineered with custom ventilation patterns, sealed cable entry glands and mounting brackets, our enclosures fully adapt to your PCB, display module and connector layout. We support tailored OEM and ODM production based on customer drawings and physical samples to meet diversified project requirements.</p> <p><strong>산준 하드웨어는 고객이 별도의 스케치를 작성할 필요 없이 바로 제작 가능한 CAD 도면을 무료로 제공합니다.</strong></p>
    더 읽어보기
    Custom brushed stainless steel edge gateway enclosure with display window, U-shaped carry handle and draw latches

    Stainless Steel Edge Gateway Enclosure Communication Case

    <p>Custom brushed 304 stainless steel edge gateway enclosure fabricated as a hinged carry case with a gasketed lid. Gasketed hinged lid with display window, two draw latches and a U-shaped carry handle for field service. We cut every port, window and boss to your PCB layout, including threaded studs and four mounting brackets. Reference size 265 x 180 x 71 mm; MOQ 1 piece, 4-7 day prototype in 0.5-20 mm stainless steel.</p>
    더 읽어보기
    Custom portable power station enclosure in blue powder-coated cold-rolled steel

    Custom Portable Power Station Enclosure Sheet Metal Case

    <p>Custom portable power station enclosure fabricated from cold-rolled steel with a durable blue powder-coated finish. Designed for outdoor mobile power stations, camping power packs and residential energy storage batteries, this sheet metal case combines laser-cut display windows, fan holes, vent louvers and USB/AC socket openings with rounded-corner bending and detachable panels for fast battery-pack assembly. We fabricate each enclosure to your internal layout – dimensions, color, cutouts, vent pattern and internal brackets are fully customizable. No mold cost, MOQ 1 piece, +/-0.1 mm tolerance, 8-10 day prototype.</p>
    더 읽어보기
    Custom AV amplifier chassis sheet metal enclosure with vent louvers and AV input panel

    Custom AV Amplifier Chassis Sheet Metal Enclosure

    <p>Custom AV amplifier chassis fabricated from cold-rolled steel with a matte black powder-coated finish. Engineered for home theater, multi-channel audio power amplifiers and commercial sound systems, this sheet metal enclosure combines laser-cut top vent louvers, reinforced front-panel cutouts and precision silkscreen markings for fiber, coaxial, AUX and Bluetooth inputs, plus subwoofer and speaker outputs. We fabricate each chassis to your panel drawings – dimensions, vent pattern, connector openings, grounding tabs and mounting brackets are fully customizable. No mold cost, MOQ 1 piece, +/-0.1 mm laser-cut tolerance, 7-10 day prototype.</p>
    더 읽어보기

    저희가 서비스를 제공했던 고객사

    선시 로고 — 판금 가공 업체
    하이센스 로고 — 판금 가공 고객사
    TCL 로고 — 판금 가공 고객사
    BOE 로고 — 판금 가공 고객사
    판금 가공 고객
    판금 가공 고객
    판금 가공 고객
    판금 가공 고객
    판금 가공 고객
    디지털 차이나 로고 — 판금 가공 업체
    스카이워스 로고 — 판금 가공 업체
    한스 레이저 로고 - 판금 가공 고객사
    로고14
    로고15
    로고16
    로고17
    로고18
    로고19
    로고20
    로고21
    로고22
    집
    왓츠앱
    이메일
    콘택트 렌즈