2U Rack Enclosure Design: Space, Cooling, Serviceability
2U Rack Enclosure Design Guide: Space, Cooling, and Serviceability

2U Rack Enclosure Design Guide: Space, Cooling, and Serviceability

A 2U rack enclosure has to hold three demands in balance at once. It has to fit cards and modules into 3.5 inches of vertical rack space. It has to pull heat out before the temperature climbs. And it has to let a technician swap a failed unit without unracking the whole stack. Good 2U rack enclosure design treats these as one connected problem, not three separate ones.

In this guide to 2U rack enclosure design we will focus on three key decisions – the space in the enclosure, the cooling path within it and the degree of serviceability. SanJun Hardware is a sheet metal fabrication manufacturer with over 15 years’ experience of producing OEM and ODM enclosures. We manufacture a wide variety of custom 2U chassis and rack enclosures from customer-supplied drawings.

Sheet metal louvers optimize airflow while protecting industrial enclosures

What a 2U Rack Enclosure Design Must Balance

A 2U unit occupies a nominal 3.5 inches (88.9 mm) of vertical rack space in a 19 inch rack. Within this space resides the card cage, the power supply, the backplane and the space for air that is left.

The need to utilize space and cooling conflicts with each other. The depth of each guide rail and divider takes precedence over the required airflow path. In reality adding parts is not the work of a guidance system, it is maintaining an airflow path after parts have been installed.

Serviceability goes in a third direction. The more heat and structure you want, the more complex it gets for the technician. Each millimeter should be spent on good design.

Space Budget and Panel Layout

Card Spacing, Panel Depth, and Cable Clearance

The card spacing is a ceiling for the rest of the component spacing. Card spacing should allow for connector keep-outs, airflow, electrical clearances and service access rather than board thickness alone.

How much rear depth is available and how does this get split between the backplane, cable bend radius and strain relief? Establish a cable bend radius for the rear harness to prevent cable stress on connectors.

Keep the cable channel clear. A short service loop tied off with a clip point keeps excess cable out of the intake and provides a means for the technician to pull the cable.

Front-Panel I/O and Access

The front panel of the PCB is where the connectors, LEDs, handles and latches live. Size connector cutouts from the connector manufacturer’s recommended panel dimensions, with the required assembly and manufacturing tolerances. Make sure there is enough pull relief at the back of the PCB so that even when pulled hard a cable cannot pull the PCB.

Position the status LEDs and handles so they are still visible and useable once a unit is racked next to other units of similar height. Consider the rear of the unit as well. Having the power connectors and secondary I/O on the back of the rear panel keeps the front clean and allows for shorter internal cabling.

Cooling a 2U Chassis

Industrial enclosure louvers and filter fans for cooling and protection

Front-to-Back Airflow and Vent Placement

For most 2U chassis, air flows from front to rear of the case, entering at the front as cool air and leaving at the rear as hot air. Therefore the intake and exhaust cutouts must be aligned to this airflow path, not simply punched in whatever flat position on the case panel is chosen.

Dividers and baffles are used internally to make air travel around the hot parts of cards, rather than behind them. This helps to stop “hot spots” from forming. As well as length of path, the pressure drop across a section must also be considered. A simple, unobstructed air intake does more work than a large open area at the back of a densely packed card cage.

Fan Cutouts and Perforation Zones

Just keep the cutout away from the fan impeller and create corresponding holes behind it. Placing a bracket against the fan blades of a design that uses fans to cool will achieve nothing.

For passive cooling units, place vent zones near the heat sources. A simple louvered or perforated band can provide airflow and help prevent accidental contact with larger objects; dust control requires appropriate filters or a separate ingress-protection design. Cooling a rack enclosure is a task that is best solved at the design stage for a panel that does not need to be reworked after the first thermal test.

Serviceability and Modular Access

Tool-Less Access and Hot-Swap

Rack gear tends to be serviced more frequently than it is installed. Convenient tool-less latches and thumb screws can simplify front or rear service while the unit remains racked. Top access requires adequate clearance or a slide-out design.

For hot-swap parts such as fans and power supplies it is important that these can be removed without touching other parts. Define slide rails and keep-outs for the modules to ensure that each module clears its neighboring modules while being slid out.

It’s worth paying a bit more for a part and keeping fastener count sensible and hardware captive. A screw falling down the back of a rack costs more to put back than the few cents’ saving.

The interior design of the case can pay off later when you want to upgrade again. With standard mounts for cards and drives, changing the inserts instead of the whole case will be easy.

Identify removable parts and keep test points clear. A good technician can identify the correct module within seconds. He can then repair a failure in your rack within a few minutes as opposed to hours.

How SanJun Hardware Builds a Custom 2U Rack Enclosure

We build 2U chassis as well as custom rack enclosures from your drawings. We start with your drawings before we cut any material.

DFM Review, Materials, and Precision

The engineering team performs a design review of the drawing for items such as card spacing, panel depth, bend radii, weld access and fastener placement. The intent is to create a chassis that holds tolerance and is easily manufactured to come off the line smoothly.

Materials to fulfill the required duty: for normal use cold-rolled steel (SPCC or Q235) is supplied in standard sizes. For corrosion resistant use stainless steel 304 or 316 is supplied. Lighter aluminum sections are used where the overall design of a particular part of the rack requires it. Galvanized steel is an intermediate option.

This product is essentially cut, bent, punched and welded on the shop floor using a combination of laser cutting, CNC bending, CNC punching, and TIG/MIG welding. The various surfaces are then finished off before any light assembly is carried out. Critical dimensions of the first article are CMM checked. The shop is a 5,000 m² facility in Guangdong, China run under ISO 9001 quality control.

Precision CMM inspection for tight-tolerance sheet metal component quality

Conclusion: Design the Three Together

Rackmount 2U enclosure design has three connected decisions: card spacing, airflow path through panels, and access path to service unit. Changing one of these decisions typically requires reconsideration of the other two.

SanJun Hardware supports custom 2U projects through DFM review and one-piece prototyping through to finishing, assembly and shipping. Get a design review on your next 2U chassis project by contacting us with your CAD files and the airflow and service requirements you are targeting.

FAQ

Q: What does 2U mean in a rack enclosure?

The term 1U refers to a rack unit that is 1.75 inches (44.45 mm) high for a 19-inch wide rack. Therefore, 2U represents a nominal rack height of 3.5 inches (88.9 mm). The actual panel height should allow appropriate installation clearance. However, the interior depth, card layout and cooling can be designed as needed.

Q: What cooling works best for a 2U chassis?

This all depends on the heat load. Lower heat loads may use passive ventilation with appropriately positioned inlet and outlet vents. Higher loads commonly require fans which have matching cutouts and perforations, often arranged for front-to-back airflow. Size the vent area to the heat load it is required to remove and align intake vents with corresponding exhaust vents.

Q: Can a 2U rack enclosure be fully customized?

Yes. SanJun Hardware makes custom 2U chassis and rack enclosures. We do a design review for space, airflow and access before starting any project. A single prototype can be made from a one-piece MOQ.

Q: What lead time and MOQ should I expect for a custom 2U enclosure?

One-piece MOQ for samples. Standard parts are typically produced within 7-15 working days, while more complex custom enclosures may require around 20-30 working days depending on design and finish. Final lead time is confirmed with the quotation. 12-24 months warranty.

ラベル:

コメント

    あなたの名前*
    Eメール*
    お電話番号*
    WhatsApp*
    メッセージ*
    ファイルが選択されていません

    目次

    FAQ

    はい。1台から対応可能で、金型費用も不要です。カスタム板金筐体はすべて、お客様の設計に基づいて直接製造できます。.
    はい、2D/3D図面に基づいたカスタム板金加工を承ります。無料のDFMチェックを提供し、お客様の正確な材質、公差、仕上げの要件に従います。試作品および量産の両方に対応可能で、厳格な品質管理と輸出基準の梱包を行います。.
    もちろんです。製品サイズ、組立機能、使用シナリオ、性能要件をお送りください。当社の板金チームが、構造設計、ソリューション調整、DFM解析を無料で提供いたします。 図面をご用意いただく必要はありません。スケッチから製造図面まで、設計作業はすべて当社にお任せください。お客様の研究開発コストとリスクを削減いたします。組立ニーズに完璧に対応できるよう、図面は繰り返し修正いたします。
    技術要件受領後、24時間対応のDFM図面レビューと正式な見積もりをご提供いたします。.
    はい。図面に基づいて迅速な試作品サンプリングを提供し、量産注文の前に構造とサイズを確認していただけるよう支援いたします。.
    弊社の製品はすべて、ISO9001、EMC、LVD、RoHS認証を取得しております。 グローバルな安全および品質基準を完全に遵守し、あらゆるプロジェクトアプリケーションに安定した信頼性の高いソリューションを提供いたします。.
    自社工場を保有し、ワンストップの社内一貫生産を提供しています。 厳格な工程管理と標準化された品質管理により、安定した製品品質と納期厳守を保証し、信頼できる長期的なグローバルパートナーシップを構築しています。.
    ステンレス鋼(304/316)、アルミニウム(5052/6061)、冷延鋼/熱延鋼、亜鉛めっき鋼、真鍮、銅など、標準および高性能の板金材料を幅広く加工しています。プロジェクトの要件に応じて、特殊材料の調達も可能です。.
    レーザー切断および曲げ加工における当社の標準加工公差は±0.1mmです。高精度部品については、材料の厚さや部品の構造に応じて、±0.05mmまで対応可能です。すべての寸法は、お客様の要件を満たすよう、出荷前に100%規格に基づき検査されます。.
    はい、粉体塗装、塗装、アルマイト処理、サンドブラスト、ヘアライン加工、電解めっき、不動態化処理、研磨、熱処理を含む、ワンストップでの全面的な表面処理サービスを提供しています。お客様のデザインに合わせて、色や仕上がりをカスタマイズできます。.
    はい、お客様から図面やデザインの詳細を受け取る前に、必ず秘密保持契約(NDA)を締結いたします。お客様の知的財産を厳重に保護し、すべてのプロジェクトを機密として扱います。.
    最新製品

    製品の表示

    さらに見る
    給水口、排水口、排水ポートを備えたカスタム機器用電源シャーシの板金筐体

    カスタム電源シャーシ板金筐体

    <p>カスタムアルミニウム製電源シャーシ筐体。サンドブラスト加工による陽極酸化処理仕上げ、レーザーカット。給水口/排水口、排水口、ハニカム構造の通気口付き。最小注文数量1個。</p>
    詳細を読む
    ディスプレイ画面とI/Oポートを備えたカスタムポータブル電源筐体(板金製)

    ポータブル電源ステーション用カスタム板金筐体

    <p>ポータブル電源およびエネルギー貯蔵装置用のカスタム6061アルミニウム筐体。サンドブラスト陽極酸化仕上げ、レーザーカット、精密曲げ加工。LCD、ACコンセント、USBポートの切り欠き、シルクスクリーン印刷対応。最小注文数量1個。</p>
    詳細を読む
    ソーラー充電コントローラー用のLCDディスプレイウィンドウとプッシュボタン穴を備えた、カスタム仕様の黒色壁掛け式電子機器筐体

    カスタム壁掛け式電子機器筐体 板金ボックス

    <p>太陽光発電用充電コントローラー、バッテリー管理システム、産業用計測機器向けのカスタム壁掛け式電子機器筐体。LCDウィンドウ、ボタン、端子の切り抜き加工、アルミニウムまたはスチール製、シルクスクリーン印刷ラベル付き。最小注文数量1個。</p>
    詳細を読む

    クライアント実績

    SUNSEAのロゴ — 板金加工のクライアント
    ハイセンスのロゴ — 板金加工のクライアント
    TCLのロゴ — 板金加工の顧客
    BOEロゴ — 板金加工のクライアント
    板金加工の顧客
    板金加工の顧客
    板金加工の顧客
    板金加工の顧客
    板金加工の顧客
    デジタルチャイナのロゴ — 板金加工のクライアント
    スカイワースのロゴ — 板金加工のクライアント
    Han's Laserのロゴ — 板金加工の顧客
    ID 14
    ID 15
    ID 16
    ID 17
    ID 18
    ロゴ19
    ID 20
    ロゴ21
    ロゴ22
    家(いえ)
    WhatsApp
    メール
    連絡先